Product Code : EL-G-11704
Edu Lab China is a leading Computerized Centrifugal Pump Trainer Manufacturer,and suppliers in China, Computerized Centrifugal Pump Trainer Manufacturer,and suppliers in China, Computerized Centrifugal Pump Trainer Algeria (Algiers), Computerized Centrifugal Pump Trainer Angola (Luanda), Computerized Centrifugal Pump Trainer Argentina (Buenos Aires), Computerized Centrifugal Pump Trainer Armenia (Yerevan), Computerized Centrifugal Pump Trainer Australia (Canberra), Computerized Centrifugal Pump Trainer Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).
Description:
• The trainer includes a closed water circuit and a powerful, standard centrifugal pump.
• Standard pumps are built according to industrial standards.
• The standard defines rating schemes and key dimensions so that standard pumps from different manufacturers can be exchanged without replacing the piping and ground plate
• A three-phase motor powers the centrifugal pump.
• The speed can be adjusted to the desired value with the frequency converter.
• An inductive, non-contact position encoder on the engine shaft records the speed.
• The drive motor is mounted in a pendulum bearing such that the drive torque can be measured with a force sensor and the mechanical drive power can be determined.
• Manometers display the pressure on the pump’s inlet and outlet.
• The flow rate is measured with an electromagnetic flow rate sensor.
• The flow rate can also be determined by means of a differential pressure measurement on an orifice plate flow meter.
• The speed, torque, and electrical power consumption of the pump and the flow rate are shown on a digital display on the switch cabinet.
FEATURES:
• Determination of the flow rate by means of an electromagnetic flow rate sensor or an orifice plate flow meter and a differential pressure measurement
• Principle of operation of a centrifugal pump
• Closed water circuit
• Recording of pump characteristics
• Recording of system characteristics
• Manometer at the inlet and outlet of the centrifugal pump
• Calculation of efficiencies
SPECIFICATION:
• Tank volume: 96L
• 230V, 50Hz, 1 phase
• 230V, 60Hz, 3 phases
Centrifugal pump :
• Max. Flow rate: approx. 15m3/h
• Max. Head: approx. 16m
Drive motor with variable speed :
• Power output: 1,1kW
• Speed range: 0…2400min-1
Measuring ranges :
• Pressure: 1x -0,6…0bar, 1x 0…2,5bar
• Flow rate: 5…600L/min
• Speed: 0…5000min -1
• Torque: 0…10Nm
• Power consumption: 0…2,2kW
DIMENSIONS AND WEIGHT:
• LxWxH: 2000x750x1480mm
• Weight: approx. 215kg